CS5480 Overview
Product Features
Superior analog performance with ultra-low noise level and high SNR
Energy measurement accuracy of 0.1% over 4000:1 dynamic range
Current RMS measurement accuracy of 0.1% over 1000:1 dynamic range
3 independent 24 bit, 4th order Delta Sigma modulators for voltage and current measurements
3 configurable digital outputs for energy pulses, zero crossing or energy direction
Supports shunt resistor, CT and Rogowski coil current sensors
Overcurrent, voltage sag and voltage swell detection
UART / SPI serial interface
Internal register protection via checksum and write-protection
On-chip voltage reference (25 ppm/°C typ.)
Single 3.3V power supply
Low power consumption: < 13mW
CS5480: 4mm x 4mm 24-pin QFN ackage
On-chip measurements / calculations:
Parametric Specifications
| Package | 24 QFN |
| Serial Comm | SPI-UART |
| Digital Outputs | 3x Configurable Outputs |
| THD (dB) | 100 |
| ADC Converters | 3 |
| Analog Power Supply (V) | 3.3 |
| Digital Power Supply (V) | 3.3 |
| Power Consumption (mW) | 13 |
| Active Power Accuracy | 0.1% over 4000:1 dynamic range |
| Current RMS Accuracy | 0.1% over 1000:1 dynamic range |
| Current Sensor Options | Shunt resistor, current transformer, or Rogowski coil |
| Power Factor Accuracy | +/-0.1% over 1000:1 dynamic range |
| Reactive Power Accuracy | 0.1% over 4000:1 dynamic range |
| Voltage RMS Accuracy | +/-0.1% over 20:1 dynamic range |
| Voltage Sensor Options | Resistor divider or transformer |